Wagner ProCoat Plus Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
English
20
Long Term
Storage
Start
You will need:
Multi-Purpose Oil
Rags
IMPORTANT: Store the
unit indoors with the
power cord wrapped
around the cord holder.
1. Carefully tilt the sprayer on
its back.
Squeeze the ears (a) on
the suction tube clip and
slide out of the inlet tting.
5. Turn power OFF. 4. Cover the outlet valve with a rag.
Turn power ON and let the pump
run for ve seconds.
2. Remove the suction tube.
Using a wrench, remove
the spray hose.
6. Replace suction tube. Insert
suction tube into the inlet valve
housing and secure with the
suction tube clip (b).
3. Careully tilt the sprayer upside-down.
Squirt approximately 2 ounces of Multi-
Purpose Oil into the inlet tting.
7. Wipe entire unit, hose,
and spray gun to remove
accumulated spray material.
MULTI-PURPOSE
OIL
(a)
l
O
1
5
(b)
2
6
3
74
MULTI-PURPOSE
OIL
OFF
5 SECONDS
l
O
ON
Vista de pagina 19